Leave a message
Product

5-46KV Concentric Neutral Cables

The product is used in power transmission and distribution line at Voltage Up to 46KV. It does not only have excellent electric, mechanical properties, but also has powerful resistance against chemical corrosion, heat aging and environmental stress.

  • Application The product is used in power transmission and distribution line at Voltage Up to 46KV. It does not only have excellent electric, mechanical properties, but also has powerful resistance against chemical corrosion, heat aging and environmental stress.
  • Standard IEC60502, SANS 1339, BS 6622, AS/NZS1429.1, NFC 33226,   CSA C 68.3, ICEA S 93-639 ,  ICEA S 94-649
  • Construction Al/Cu Conductor, XLPE Insulation, Cu Tape/Copper Wire Metallic Screen ,  Tape/ Wire Armor(Optional), PVC /PE Outer Jacket.

Application

The product is used in power transmission and distribution line at Voltage Up to 46KV. It does not only have excellent electric, mechanical properties, but also has powerful resistance against chemical corrosion, heat aging and environmental stress.

Standard IEC60502, SANS 1339, BS 6622, AS/NZS1429.1, NFC 33226,   CSA C 68.3, ICEA S 93-639 ,  ICEA S 94-649

Construction Al/Cu Conductor, XLPE Insulation, Cu Tape/Copper Wire Metallic Screen ,  Tape/ Wire Armor(Optional), PVC /PE Outer Jacket

Product Data Sheet

Table1-Conductor Construction

Conductor Size Min Stranding No. Nominal Diameter Max. D.C. Resistance at 20℃
AWG/ kcmil mm2 mm mm Ω/KM
3 26.7 6 6.05 0.68509
2 33.6 6 6.81 0.54357
1 42.4 7 7.59 0.43099
1/0 53.5 7 8.53 0.34094
2/0 67.4 12 9.55 0.27082
3/0 85 15 10.7 0.21453
4/0 107 17 12.1 0.16854
250 127 18 13.2 0.14409
300 152 18 14.5 0.12029
350 177 24 15.6 0.10292
400 203 24 16.7 0.08909
500 253 30 18.7 0.07140
550 279 34 19.7 0.06561
600 304 34 20.7 0.06015
700 355 34 22.3 0.05114
750 380 53 23.1 0.04760
800 405 53 23.8 0.04471
1000 507 53 26.9 0.03570

Table2-Insulation, Metallic shield Dimension

Rated Circuit Voltage, Phase-to-Phase Conductor Size XLPE/TRXLPE  Insulation Nominal Thickness Metal Screen
100 Percent Level 133 Percent Level 173 Percent Level Copper Tape
V AWG/kcmil mm mm mm mm
2001-5000 8-1000 2.3 2.3 3.6 0.06
1001-3000 3.6 3.6 3.6 0.06
5001-8000 6-1000 2.9 3.6 4.4 0.06
1001-3000 4.4 4.4 5.6 0.06
8001-15000 2-1000 4.4 5.6 6.6 0.06
1001-3000 5.6 5.6 6.6 0.06
15001-25000 1-3000 6.6 8.1 10.7 0.06
25001-28000 1-3000 7.1 8.8 11.3 0.06
28001-35000 1/0-3000 8.8 10.7 14.7 0.06
35001-46000 4/0-3000 11.3 14.7 19.1 0.06

Table3-Concentric conductor dimension for Concentric Neutral Cables

Concentric Neutral Wire Size
AWG Size Nominal Diameter Nominal Area
mils mm (kcmil)
16 50.8 1.29 2.58
14 64.1 1.63 4.11
12 80.8 2.05 6.53
10 101.9 2.59 10.38
9 114.4 2.91 13.09
8 128.5 3.26 16.51

 

Full Neutral Concentric Copper Conductor
Conductor Size AWG/kcmil Concentric Conductor Minimum Number  of Wires
Copper Aluminum 16AWG 14AWG 12AWG 10AWG 9AWG
4 10* 6
4 2 16* 10
3 1 20* 13
2 1/0 26* 16 10*
1 2/0 20* 13
1/0 3/0 25* 16 10*
2/0 4/0 32* 20* 13 10*
3/0 250 25* 16 13*
4/0 350 32* 20* 16

One-third Neutral Concentric Copper Conductor
Conductor Size

AWG/kcmil

Concentric Conductor Minimum Number  of Wires
Copper Aluminum 16AWG 14AWG 12AWG 10AWG 9AWG 8AWG
2 1/0 9 6
1 2/0 11 7
1/0 3/0 14 9 6*
4/0 17 11 7*
2/0 18 11 7*
250 20 13 8*
3/0 22 14 9* 6*
4/0 350 28* 18 11* 7* 6*
250 21 13* 9* 7*
500 25* 16 10* 8* 7*
350 29* 18 12* 9* 8*
600 30* 19 12* 10* 8*
750 24 15* 12* 10*
500 26* 17 13* 10*
600 1000 31* 20 16* 13*
650 34* 21 17* 14*
750 1250 25* 20 16*
1500 30* 24 19*
1000 32* 26* 21
*Alternate constructions

Table4-Thickness of bedding and size of armor wire

Calculated Dia. of cable under bedding Min. thickness of bedding Nominal size of armor wire
mm mm mm
0-19.05 1.14 2.11
19.08-25.40 1.65 2.77
25.43-43.18 2.03 3.4
43.21-63.50 2.03 4.19
63.53 & larger 2.41 5.16

Packaging & Delivery

Our cables, wires, conductors are usually packed in wood drum, Iron-wooden drum.  Steel reel will also be used if required by client. For some short length, such as 50m, 150m, 300m, the conductor can also be packed in coil.

FAQ

What information should we provide to get a quotation?

Product standard, Conductor Size, Quantity, Sea port/Airport for delivery, etc.

How long time can we get your quotation?

Usually we will quote to you within 24 hours after get your detailed inquiry information

How can I know have you ever exported to our country/area? Are you familiar with our market?

We have exported to 100+ countries/area. We have rich export experience and will try our best to serve you and meet your needs.  You can contact us for detailed communications.

What trade term you offer?

Normally we offer EXW,FCA,FOB,CNF,CIF according to customer requirements.

What`s your lead time for the order?

According to different order quantity, the lead time is different.  Normally it is 7- 30 days for production. For large quantities, the goods will be shipped in partial times according to schedule.

Leave Message